Stern, R. L., Cline, H. E., Johnson, G. A., & Ravin, C. E. (1988). Development of a 3D reconstructed-image surgical planning station. Investigative Radiology, 23(9), S60–S60. https://scholars.duke.edu/display/pub655251
Sherrier, R. H., Chiles, C., Wilkinson, W. E., Johnson, G. A., & Ravin, C. E. (1988). Effects of image processing on nodule detection rates in digitized chest radiographs: ROC study of observer performance. Radiology, 166(2), 447–450. https://doi.org/10.1148/radiology.166.2.3336719
Sherrier, R. H., Suddarth, S. A., & Johnson, G. A. (1988). Film-Based Digital Tomosynthesis Of The Chest. Optical Engineering, 27(8). https://doi.org/10.1117/12.7976742
Maynor, C. H., Charles, H. C., Herfkens, R. J., Suddarth, S. A., & Johnson, G. A. (1988). Invitro chemical-shift imaging of atherosclerosis at 7.0-Tesla. Investigative Radiology, 23(9), S3–S3.
Dixon, D., Johnson, G. A., Cofer, G. P., Hedlund, L. W., & Maronpot, R. R. (1988). Magnetic resonance imaging (MRI): a new tool in experimental toxicologic pathology. Toxicol Pathol, 16(3), 386–391. https://doi.org/10.1177/019262338801600311
Effmann, E. L., Johnson, G. A., Smith, B. R., Talbott, G. A., & Cofer, G. (1988). Magnetic resonance microscopy of chick embryos in ovo. Teratology, 38(1), 59–65. https://doi.org/10.1002/tera.1420380109
Brown, J. M., Thomas, J. F., Cofer, G. P., & Johnson, G. A. (1988). Magnetic Resonance Microscopy of Stem Tissues of Pelargonium hortorum. Botanical Gazette, 149(3), 253–259. https://doi.org/10.1086/337713
Conner, W. E., Johnson, G. A., Cofer, G. P., & Dittrich, K. (1988). Magnetic resonance microscopy: in vivo sectioning of a developing insect. Experientia, 44(1), 11–12. https://doi.org/10.1007/bf01960223
Spritzer, C. E., Vogler, J. B., Martinez, S., Garrett, W. E., Johnson, G. A., McNamara, M. J., Lohnes, J., Herfkens, R. J. (1988). MR imaging of the knee: preliminary results with a 3DFT GRASS pulse sequence. Ajr Am J Roentgenol, 150(3), 597–603. https://doi.org/10.2214/ajr.150.3.597
Farmer, T. H. R., Johnson, G. A., Cofer, G. P., Maronpot, R. R., & Hedlund, L. W. (1988). MR microscopy of nephrotoxic acute tubular-necrosis in the rat. Investigative Radiology, 23(9), S10–S10. https://scholars.duke.edu/display/pub654959
Maki, J. H., Cofer, G. P., Hedlund, L. W., Macfall, J. R., & Johnson, G. A. (1988). MR microscopy using driven equilibrium (deft). Investigative Radiology, 23(9), S21–S21. https://scholars.duke.edu/display/pub655181
Maki, J. H., Johnson, G. A., Cofer, G. P., & MacFall, J. R. (1988). SNR improvement in NMR microscopy using DEFT. Journal of Magnetic Resonance (1969), 80(3), 482–492. https://doi.org/10.1016/0022-2364(88)90243-0
Dockery, S., Suddarth, S. A., Cofer, G. P., & Johnson, G. A. (1988). The impact of increased spin-lattice relaxation-time microscopy at 7.0T. Investigative Radiology, 23(9), S20–S20.